logo
produkty
szczegółowe informacje o produktach
Dom > produkty >
UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm

MOQ: 1
Cena £: negocjowalne
Standardowe Opakowanie: Aluminium Box
Okres dostawy: 3 Days
Metoda płatności: T/T
Wydajność dostaw: 100 sets per month
Szczegółowe informacje
Place of Origin
China
Nazwa handlowa
Sinuo
Orzecznictwo
Calibration Certificate (Cost Additional)
Model Number
SN2210-38
Applied Standard:
UL1017
Applied Figure:
Figure 3
Probe length:
101.6 mm
Head Diameter:
12.7 mm
Former Head Radius:
6.4 mm
Tail Diameter:
19.1 mm
Opis produktu

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm
 

Product Overview:

 

UL 1017 is a safety standard titled “Standard for Vacuum Cleaners, Blower Cleaners, and Household Floor Finishing Machines.” Figure 3 in this standard refers to the Straight Probe, which is used in accessibility and entrapment testing to simulate a person’s finger or object interaction.

 

Standard:UL1017 Figure 3, UL982 Figure 64.8, UL398 Figure 8.2 (PA170B), UL507 (PA170D), UL749 Figure 2, UL982 Figure 58.7 and UL1278 Figure 8.2 (PA140A)

Application:It is used for testing of enamel coated wires (i.e. transformers and inductors)

Test sample:Transformers and Inductors

Feature:Nylon handle + probe, it is manufactured according to the standard figure.

Standard figure:

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm 0

 

Fearures:

 

Feature Specification
Type Straight Probe
Purpose To test accessibility to hazardous moving parts or live parts
Design Cylindrical rod with specific length and diameter
Material Typically metal or rigid plastic (non-deforming)
Tip Flat or slightly rounded (non-sharp)
Dimensions As defined in the standard – follows finger simulation specs
Use Case Inserted into openings to test for unsafe access
Testing Scenario Applied with force or weight per standard test conditions

 

Probe Dimension:

 

Probe Length: 101.6 mm
Head Diameter: 12.7 mm
Former Head Radius: 6.4 mm
Tail Diameter:19.1 mm

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm 1

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm 2

produkty
szczegółowe informacje o produktach
UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm
MOQ: 1
Cena £: negocjowalne
Standardowe Opakowanie: Aluminium Box
Okres dostawy: 3 Days
Metoda płatności: T/T
Wydajność dostaw: 100 sets per month
Szczegółowe informacje
Place of Origin
China
Nazwa handlowa
Sinuo
Orzecznictwo
Calibration Certificate (Cost Additional)
Model Number
SN2210-38
Applied Standard:
UL1017
Applied Figure:
Figure 3
Probe length:
101.6 mm
Head Diameter:
12.7 mm
Former Head Radius:
6.4 mm
Tail Diameter:
19.1 mm
Minimum Order Quantity:
1
Cena:
negocjowalne
Packaging Details:
Aluminium Box
Delivery Time:
3 Days
Payment Terms:
T/T
Supply Ability:
100 sets per month
Opis produktu

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm
 

Product Overview:

 

UL 1017 is a safety standard titled “Standard for Vacuum Cleaners, Blower Cleaners, and Household Floor Finishing Machines.” Figure 3 in this standard refers to the Straight Probe, which is used in accessibility and entrapment testing to simulate a person’s finger or object interaction.

 

Standard:UL1017 Figure 3, UL982 Figure 64.8, UL398 Figure 8.2 (PA170B), UL507 (PA170D), UL749 Figure 2, UL982 Figure 58.7 and UL1278 Figure 8.2 (PA140A)

Application:It is used for testing of enamel coated wires (i.e. transformers and inductors)

Test sample:Transformers and Inductors

Feature:Nylon handle + probe, it is manufactured according to the standard figure.

Standard figure:

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm 0

 

Fearures:

 

Feature Specification
Type Straight Probe
Purpose To test accessibility to hazardous moving parts or live parts
Design Cylindrical rod with specific length and diameter
Material Typically metal or rigid plastic (non-deforming)
Tip Flat or slightly rounded (non-sharp)
Dimensions As defined in the standard – follows finger simulation specs
Use Case Inserted into openings to test for unsafe access
Testing Scenario Applied with force or weight per standard test conditions

 

Probe Dimension:

 

Probe Length: 101.6 mm
Head Diameter: 12.7 mm
Former Head Radius: 6.4 mm
Tail Diameter:19.1 mm

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm 1

 

UL 1017 Figure 3 Straight Probe For Testing Of Enamel Coated Wires Probe length 101.6mm 2

Sitemap |  Polityka prywatności | Chiny dobre. Jakość Sprzęt do testowania urządzeń elektrycznych Sprzedawca. 2019-2025 Sinuo Testing Equipment Co. , Limited . Wszystko Prawa zastrzeżone.