Wyślij wiadomość
produkty
szczegółowe informacje o produktach
Dom > produkty >
IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control

MOQ: 1
Cena £: Customized
Standardowe Opakowanie: Plywood Case
Okres dostawy: 30 days
Metoda płatności: T/T
Wydajność dostaw: 10 Sets / Month
Szczegółowe informacje
Place of Origin
China
Nazwa handlowa
Sinuo
Orzecznictwo
Calibration Certificate (Cost Additional)
Model Number
SN2116E
Test times:
0~999999 times
Drive mode:
Servo motor drive
Test stroke:
0~100mm
Test speed:
0~100mm/s
Conduction time:
0~99.9s
Non-conduction time:
0~99.9s
Test angle:
0~360°
Angle gears:
1-15 gears
Minimum Order Quantity:
1
Cena:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 days
Payment Terms:
T/T
Supply Ability:
10 Sets / Month
Opis produktu

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control

 

Product overview:

 

The test equipment has 6 work stations: 3 linear stations synchronously, which can test 3 linear rocker switches and push-button switches, the other 3 rotary stations synchronously, which can test 3 tumbler switches at the same time. The equipment will automatically stop and alarm if one of the stations in abnormal running.

 

This device complies with standard terms of IEC 60884-1: 2022 clause 20 and 21, figure 22, IEC60669-1:2017 clause 18 & 19, etc.

 

Working together with load cabinet, can achieve making and breaking ability test and the normal operation endurance test of the plugs, sockets and linear switches for household and similar fixed-electrical installations. The testing purpose is to see whether the switches or the plugs and sockets can endurance the mechanical damage or electric fatigue failure during the normal operation. Whether the contact adhesion occurs or there is a phenomenon of being the on (off) station for a long time, which is the criterion of judging the sample is over damage or not.

 

The device is made of aluminum alloy rack, stainless steel seal plate, driven by a servo motor and ball screw, 7-inch color touch-screen display and set the test parameters, PLC control. Preset number of trials, testing rate, and stroke.

 

Technical Parameters:

 

No. Item Parameters Remark
1 Power AC 220V±10V, 60Hz  
2 Station 6 stations (3 linear stations synchronously for testing plugs, sockets, linear switches; 3 rotary stations synchronously for testing rotary switches)  
3 Operation interface 7-inch color LCD touch screen  
4 Drive mode Servo motor + ball screw  
5 Control system PLC control system

Mitsubishi

 

6 Test times 0~999999 times, can be preset  
7 Conduction time 0~99.9s, can be preset  
8 Non-conduction time 0~99.9s,can be preset  
9 Test stroke Linear: 0~100mm, can be preset  
Rotary: 1~360°,can be preset  
10 Test speed

Linear: 0~100mm/s,can be preset

Rotary: 0~360°/s, can be preset

 
11 Test angle 0~360°,can be preset  
12 Test angle gears 1-15 gears, can be preset  
13 Sample fixtures One universal fixture with different auctors to adapt to different switches  
14 Atmospheric pressure 80~106kpa  
15 Ambient temperature 5~40°C  
16 Relative humidity (20~90)%RH  
17 Use environment Requires no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gases, needs good heat dissipation place  
18 Dimensions and weight L*W*H=960*730*600mm,160kg  

 

Every Other Output Function:

 

This tester has function: Every other output function, which is mainly used in the plug and socket test. After the load current is connected and the current detection function is turned on, when the plug is inserted into the socket for the first time, the program controls the current of the load cabinet to flow through the socket, and then closes the load cabinet after pulling it out. When the plug is inserted into the socket for the second time, no current flows through the socket, there is current for the third time, and there is no current for the fourth time. In this cycle, the purpose of intermittent power-on is achieved.

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control 0

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control 1

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control 2

produkty
szczegółowe informacje o produktach
IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control
MOQ: 1
Cena £: Customized
Standardowe Opakowanie: Plywood Case
Okres dostawy: 30 days
Metoda płatności: T/T
Wydajność dostaw: 10 Sets / Month
Szczegółowe informacje
Place of Origin
China
Nazwa handlowa
Sinuo
Orzecznictwo
Calibration Certificate (Cost Additional)
Model Number
SN2116E
Test times:
0~999999 times
Drive mode:
Servo motor drive
Test stroke:
0~100mm
Test speed:
0~100mm/s
Conduction time:
0~99.9s
Non-conduction time:
0~99.9s
Test angle:
0~360°
Angle gears:
1-15 gears
Minimum Order Quantity:
1
Cena:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 days
Payment Terms:
T/T
Supply Ability:
10 Sets / Month
Opis produktu

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control

 

Product overview:

 

The test equipment has 6 work stations: 3 linear stations synchronously, which can test 3 linear rocker switches and push-button switches, the other 3 rotary stations synchronously, which can test 3 tumbler switches at the same time. The equipment will automatically stop and alarm if one of the stations in abnormal running.

 

This device complies with standard terms of IEC 60884-1: 2022 clause 20 and 21, figure 22, IEC60669-1:2017 clause 18 & 19, etc.

 

Working together with load cabinet, can achieve making and breaking ability test and the normal operation endurance test of the plugs, sockets and linear switches for household and similar fixed-electrical installations. The testing purpose is to see whether the switches or the plugs and sockets can endurance the mechanical damage or electric fatigue failure during the normal operation. Whether the contact adhesion occurs or there is a phenomenon of being the on (off) station for a long time, which is the criterion of judging the sample is over damage or not.

 

The device is made of aluminum alloy rack, stainless steel seal plate, driven by a servo motor and ball screw, 7-inch color touch-screen display and set the test parameters, PLC control. Preset number of trials, testing rate, and stroke.

 

Technical Parameters:

 

No. Item Parameters Remark
1 Power AC 220V±10V, 60Hz  
2 Station 6 stations (3 linear stations synchronously for testing plugs, sockets, linear switches; 3 rotary stations synchronously for testing rotary switches)  
3 Operation interface 7-inch color LCD touch screen  
4 Drive mode Servo motor + ball screw  
5 Control system PLC control system

Mitsubishi

 

6 Test times 0~999999 times, can be preset  
7 Conduction time 0~99.9s, can be preset  
8 Non-conduction time 0~99.9s,can be preset  
9 Test stroke Linear: 0~100mm, can be preset  
Rotary: 1~360°,can be preset  
10 Test speed

Linear: 0~100mm/s,can be preset

Rotary: 0~360°/s, can be preset

 
11 Test angle 0~360°,can be preset  
12 Test angle gears 1-15 gears, can be preset  
13 Sample fixtures One universal fixture with different auctors to adapt to different switches  
14 Atmospheric pressure 80~106kpa  
15 Ambient temperature 5~40°C  
16 Relative humidity (20~90)%RH  
17 Use environment Requires no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gases, needs good heat dissipation place  
18 Dimensions and weight L*W*H=960*730*600mm,160kg  

 

Every Other Output Function:

 

This tester has function: Every other output function, which is mainly used in the plug and socket test. After the load current is connected and the current detection function is turned on, when the plug is inserted into the socket for the first time, the program controls the current of the load cabinet to flow through the socket, and then closes the load cabinet after pulling it out. When the plug is inserted into the socket for the second time, no current flows through the socket, there is current for the third time, and there is no current for the fourth time. In this cycle, the purpose of intermittent power-on is achieved.

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control 0

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control 1

 

IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control 2

Sitemap |  Polityka prywatności | Chiny dobre. Jakość Sprzęt do testowania urządzeń elektrycznych Sprzedawca. 2019-2024 sinuotek.com . Wszystko Prawa zastrzeżone.