MOQ: | 1 |
Cena £: | Customized |
Standardowe Opakowanie: | Plywood Case |
Okres dostawy: | 30 days |
Metoda płatności: | T/T |
Wydajność dostaw: | 10 Sets / Month |
IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control
Product overview:
The test equipment has 6 work stations: 3 linear stations synchronously, which can test 3 linear rocker switches and push-button switches, the other 3 rotary stations synchronously, which can test 3 tumbler switches at the same time. The equipment will automatically stop and alarm if one of the stations in abnormal running.
This device complies with standard terms of IEC 60884-1: 2022 clause 20 and 21, figure 22, IEC60669-1:2017 clause 18 & 19, etc.
Working together with load cabinet, can achieve making and breaking ability test and the normal operation endurance test of the plugs, sockets and linear switches for household and similar fixed-electrical installations. The testing purpose is to see whether the switches or the plugs and sockets can endurance the mechanical damage or electric fatigue failure during the normal operation. Whether the contact adhesion occurs or there is a phenomenon of being the on (off) station for a long time, which is the criterion of judging the sample is over damage or not.
The device is made of aluminum alloy rack, stainless steel seal plate, driven by a servo motor and ball screw, 7-inch color touch-screen display and set the test parameters, PLC control. Preset number of trials, testing rate, and stroke.
Technical Parameters:
No. | Item | Parameters | Remark |
1 | Power | AC 220V±10V, 60Hz | |
2 | Station | 6 stations (3 linear stations synchronously for testing plugs, sockets, linear switches; 3 rotary stations synchronously for testing rotary switches) | |
3 | Operation interface | 7-inch color LCD touch screen | |
4 | Drive mode | Servo motor + ball screw | |
5 | Control system | PLC control system |
Mitsubishi
|
6 | Test times | 0~999999 times, can be preset | |
7 | Conduction time | 0~99.9s, can be preset | |
8 | Non-conduction time | 0~99.9s,can be preset | |
9 | Test stroke | Linear: 0~100mm, can be preset | |
Rotary: 1~360°,can be preset | |||
10 | Test speed |
Linear: 0~100mm/s,can be preset Rotary: 0~360°/s, can be preset |
|
11 | Test angle | 0~360°,can be preset | |
12 | Test angle gears | 1-15 gears, can be preset | |
13 | Sample fixtures | One universal fixture with different auctors to adapt to different switches | |
14 | Atmospheric pressure | 80~106kpa | |
15 | Ambient temperature | 5~40°C | |
16 | Relative humidity | (20~90)%RH | |
17 | Use environment | Requires no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gases, needs good heat dissipation place | |
18 | Dimensions and weight | L*W*H=960*730*600mm,160kg |
Every Other Output Function:
This tester has function: Every other output function, which is mainly used in the plug and socket test. After the load current is connected and the current detection function is turned on, when the plug is inserted into the socket for the first time, the program controls the current of the load cabinet to flow through the socket, and then closes the load cabinet after pulling it out. When the plug is inserted into the socket for the second time, no current flows through the socket, there is current for the third time, and there is no current for the fourth time. In this cycle, the purpose of intermittent power-on is achieved.
MOQ: | 1 |
Cena £: | Customized |
Standardowe Opakowanie: | Plywood Case |
Okres dostawy: | 30 days |
Metoda płatności: | T/T |
Wydajność dostaw: | 10 Sets / Month |
IEC 60669-1 Switch Plug Socket Endurance Tester 6 Linear And Rotary Stations PLC Control
Product overview:
The test equipment has 6 work stations: 3 linear stations synchronously, which can test 3 linear rocker switches and push-button switches, the other 3 rotary stations synchronously, which can test 3 tumbler switches at the same time. The equipment will automatically stop and alarm if one of the stations in abnormal running.
This device complies with standard terms of IEC 60884-1: 2022 clause 20 and 21, figure 22, IEC60669-1:2017 clause 18 & 19, etc.
Working together with load cabinet, can achieve making and breaking ability test and the normal operation endurance test of the plugs, sockets and linear switches for household and similar fixed-electrical installations. The testing purpose is to see whether the switches or the plugs and sockets can endurance the mechanical damage or electric fatigue failure during the normal operation. Whether the contact adhesion occurs or there is a phenomenon of being the on (off) station for a long time, which is the criterion of judging the sample is over damage or not.
The device is made of aluminum alloy rack, stainless steel seal plate, driven by a servo motor and ball screw, 7-inch color touch-screen display and set the test parameters, PLC control. Preset number of trials, testing rate, and stroke.
Technical Parameters:
No. | Item | Parameters | Remark |
1 | Power | AC 220V±10V, 60Hz | |
2 | Station | 6 stations (3 linear stations synchronously for testing plugs, sockets, linear switches; 3 rotary stations synchronously for testing rotary switches) | |
3 | Operation interface | 7-inch color LCD touch screen | |
4 | Drive mode | Servo motor + ball screw | |
5 | Control system | PLC control system |
Mitsubishi
|
6 | Test times | 0~999999 times, can be preset | |
7 | Conduction time | 0~99.9s, can be preset | |
8 | Non-conduction time | 0~99.9s,can be preset | |
9 | Test stroke | Linear: 0~100mm, can be preset | |
Rotary: 1~360°,can be preset | |||
10 | Test speed |
Linear: 0~100mm/s,can be preset Rotary: 0~360°/s, can be preset |
|
11 | Test angle | 0~360°,can be preset | |
12 | Test angle gears | 1-15 gears, can be preset | |
13 | Sample fixtures | One universal fixture with different auctors to adapt to different switches | |
14 | Atmospheric pressure | 80~106kpa | |
15 | Ambient temperature | 5~40°C | |
16 | Relative humidity | (20~90)%RH | |
17 | Use environment | Requires no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gases, needs good heat dissipation place | |
18 | Dimensions and weight | L*W*H=960*730*600mm,160kg |
Every Other Output Function:
This tester has function: Every other output function, which is mainly used in the plug and socket test. After the load current is connected and the current detection function is turned on, when the plug is inserted into the socket for the first time, the program controls the current of the load cabinet to flow through the socket, and then closes the load cabinet after pulling it out. When the plug is inserted into the socket for the second time, no current flows through the socket, there is current for the third time, and there is no current for the fourth time. In this cycle, the purpose of intermittent power-on is achieved.